ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7

Published monthly
 

4E assessment and 3D parametric analysis of an innovative liquefied natural gas production process assisted by a diffusion–absorption refrigeration unit

Mehdi Mehrpooya, Seyed Ali Mousavi, Mostafa Delpisheh, Andrew Zaitsev, and Andrey Nikitin

Faculty of Cryogenic Engineering, School of Biotechnology and Cryogenic Systems, ITMO University, Saint Petersburg, Russia

 

E-mail: mmhrpuya@itmo.ru

Received: 26 January 2022  Accepted: 10 April 2022

Abstract:

Cumulative electricity demand in the world’s energy portfolio has elicited in focusing new energy carriers. Herein, a single mixed refrigerant (SMR) LNG process, precooled with a diffusion–absorption refrigeration (DAR) system, is proposed and appraised through 4E assessment and 3D parametric analyses. The SMR subsystem feeds on 63,850 kg/h of natural gas at 6650 kPa, and, utilizing 331,630 kW of waste heat, the DAR subsystem transfers 139,306 kW of refrigeration duty, at − 29.62 °C to the SMR, and thereby 57,850 kg/h LNG is produced. The results indicate the cost per unit exergy of 13.54 $/GJ and cost rate of 90.71 $/s regarding the LNG output. Also, the exergy destruction cost rate percentage share in most components is higher than the investment cost rates. The T-100 tower had the largest exergy destruction cost rate at 64,763.52 $/h, while the COMP-102 compressor had the highest investment cost rate at 1821.35 $/h. The nominal interest rate increases the exergoeconomic factor and the overall cost rate in the case of the T-100 tower. The annualized cost of system (ACS) analysis indicated the ACS at 100.458 M$/year with a levelized cost of product (LCOP) at 0.198 $/kg LNG. The exergoenvironmental evaluation signposted that the total environmental impact is the highest in air coolers AC-100 and AC-101, respectively. Finally, the 3D parametric showed that compressor C-100 isentropic efficiency and inlet temperature of the tower T-100 had non-consistent connotation, whereas compressor C-100 pressure ratio and heat exchanger HX-102 minimum approach temperature had consistent connotation.

Graphical abstract

Keywords: LNG; Life cycle assessment; Diffusion–absorption refrigeration; Exergy analysis; Exergoeconomic analysis; Annualized cost of system analysis

Full paper is available at www.springerlink.com.

DOI: 10.1007/s11696-022-02227-8

 

Chemical Papers 76 (8) 5231–5252 (2022)

Sunday, November 24, 2024

IMPACT FACTOR 2023
2.1
SCImago Journal Rank 2023
0.381
SEARCH
Advanced
VOLUMES
© 2024 Chemical Papers