ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7
Published monthly
|
Coulometric determination of organic compounds. III. Determination of some phenoxazones by titanometric coulometry
V. Stužka and V. Štefanidesová
Department of Analytical and Organic Chemistry, Faculty of Natural Sciences,
Palacký University, 771 46 Olomouc
Abstract: Conditions have been found for the determination of some phenoxazones by
titanometric coulometry using platinum electrode to generate Ti(III) ions,
while the point of equivalency was recorded potentiometrically. It has been
found, that correct and accurate results can be obtained when the amount of
ethanol in the coulometric vessel is within 2—7 ml and the amount of the
substance determined is 0.2—0,6 mg in 50—100 ml. Acetone was found
a suitable solvent in the determination of 9-diethylaminobenzo[a]phenoxaz-5-one.
Full paper in Portable Document Format: 323a366.pdf
Chemical Papers 32 (3) 366–371 (1978)
|