ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7

Published monthly
 

Optimalization of deoxyribonucleic acid extraction using various types of magnetic particles

Jana Konečná, Denisa Romanovská, Daniel Horák, and Štěpánka Trachtová

Brno University of Technology, Brno, Czech Republic

 

E-mail: xckonecnaj@fch.vutbr.cz

Abstract: Isolation of deoxyribonucleic acid is an important step in the molecular diagnostics of microorganisms. A high quality of isolated deoxyribonucleic acid is necessary for deoxyribonucleic acid amplification by the polymerase chain reaction. The conventional deoxyribonucleic acid isolation using phenol–chloroform extraction and deoxyribonucleic acid precipitation in ethanol is time-consuming and requires the use of toxic phenol. Magnetic separation techniques using magnetic solid particles are one of modern methods to speed up the nucleic acids isolation. The aim of this work was to use two different types of magnetic particles for solid-phase deoxyribonucleic acid extraction. The amounts of deoxyribonucleic acid in separation mixtures were measured using ultraviolet spectrophotometry. The first experimental conditions were tested on chicken erythrocytes deoxyribonucleic acid. Phosphate buffer (pH 7, 7.6 and 8) was used for the adsorption of deoxyribonucleic acid on magnetic particles. Tested values of pH have no effects on deoxyribonucleic acid adsorption. It was shown that approximately almost one half of deoxyribonucleic acid was adsorbed to the particles. A number of different elution conditions (temperature, time and pH value of elution buffer) were investigated to determine their effect on elution efficiency. It was shown that only a small fraction of the bound DNA was released at 22 °C, while the release was more effective as the temperature was increased also the amount of elution deoxyribonucleic acid was more effective when time was increased. The higher amounts of deoxyribonucleic acid were eluted with TE buffer pH 9.0. Second, bacterial deoxyribonucleic acid was tested. This deoxyribonucleic acid eluted from the particles was in polymerase chain reaction ready quality.

Keywords: Magnetic particles ; Solid-phase extraction ; Polymerase chain reaction ; Deoxyribonucleic acid isolation 

Full paper is available at www.springerlink.com.

DOI: 10.1007/s11696-018-00675-9

 

Chemical Papers 73 (5) 1247–1255 (2019)

Friday, April 19, 2024

IMPACT FACTOR 2021
2.146
SCImago Journal Rank 2021
0.365
SEARCH
Advanced
VOLUMES
European Symposium on Analytical Spectrometry ESAS 2022
© 2024 Chemical Papers