ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7

Published monthly
 

Pyrohydrolytic determination of fluorides. III. Optimum conditions of pyrohydrolysis

K. Matiašovský and C. Kubík

Slovak Academy of Sciences, Bratislava

 

Abstract: Various factors affecting the pyrohydrolytic detn. of F- in Al production and with TiO2 as an activator are described. The condensate is titrated with 0.2N NaOH, with phenolphthalein or cresol red indicators. It is not necessary to under-layer or over-layer the sample with the activator. The sample wt. should be ≥0.1 g., and the wt. ratio of activator to sample should be ≤5:1. The flow of the H2O vapor should be ≥5 g. H2O/min. (about 200 cm./sec.). Under these conditions, the max. error is ±0.1% relative or 0.2% abs.

Full paper in Portable Document Format: 1611a808.pdf (in Slovak)

 

Chemical Papers 16 (11) 808–817 (1962)

Wednesday, November 27, 2024

IMPACT FACTOR 2023
2.1
SCImago Journal Rank 2023
0.381
SEARCH
Advanced
VOLUMES
© 2024 Chemical Papers