ISSN print edition: 0366-6352
ISSN electronic edition: 1336-9075
Registr. No.: MK SR 9/7

Published monthly
 

Surface plasmon resonance application in prostate cancer biomarker research

Pavel Damborský, Narayanan Madaboosi, Virginia Chu, João P. Conde, and Jaroslav Katrlík

Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dúbravská cesta 9, 845 38 Bratislava, Slovakia

 

E-mail: chemjkat@savba.sk

Abstract: Prostate cancer (PCa) diagnostics can be effectively addressed using sensor-based approaches. Proper selection of biomarkers to be included in biosensors for accurate detection becomes the need of the hour. Such biosensor and biochip technologies enable fast and efficient determination of proteins and provide a remarkable insight into the changes in the protein structure, such as aberrant glycosylation, which can increase the performance, sensitivity and specificity of clinic assays. However, for a thorough comprehension of such complex protein modifications, it is crucial to understand their biospecific interactions. Surface plasmon resonance (SPR), one of the most rapidly developing techniques for measuring real-time quantitative binding affinities and kinetics of the interactions of antigens and antibodies, was chosen as an appropriate tool for this purpose. Herein, experiments on the interactions of antibodies specific against different epitopes of free and complexed prostate-specific antigen (PSA), a prominent PCa biomarker, are presented with two main aims: (i) to continue as lectin glycoprofiling studies and; (ii) to be used in microfluidic immunoassay-based platforms for point-of-care devices. Various PSA-specific antibodies were covalently immobilized on the biochip surface via amine coupling, and free or complexed PSA was injected into the dual-flow channels of the SPR device. Kinetic parameters and affinity constants of these interactions, as well as cross-reactivities of the used antibodies were determined. The sandwich assay for PSA determination was developed employing both primary and secondary anti-PSA antibodies. Sensitivity of the assay was 3.63 nM−1, the detection limit was 0.27 nM and the SPR biosensor response towards free PSA was linear up to 25 nM. All these findings are essential for proper design of a selective, sensitive, and highly reliable biosensor for PCa diagnosis as a lab-on-chip device.

Keywords: biomarker – prostate-specific antigen – prostate cancer – antibody – surface plasmon resonance – biospecific interaction

Full paper is available at www.springerlink.com.

DOI: 10.1515/chempap-2015-0053

 

Chemical Papers 69 (1) 143–149 (2015)

Tuesday, November 26, 2024

IMPACT FACTOR 2023
2.1
SCImago Journal Rank 2023
0.381
SEARCH
Advanced
VOLUMES
© 2024 Chemical Papers